The Portable Foam Fire Extinguisher is manufactured to deliver superior firefighting capability for environments where flammable liquids and combustible materials pose a risk. Using a high-quality aqueous film-forming foam (AFFF) solution, it forms a vapor-sealing blanket over burning surfaces. This suppresses flames, prevents re-ignition, and cools surrounding materials.
Built with a robust steel cylinder, pressure gauge, discharge hose, and spray nozzle, this extinguisher is engineered for reliable performance and ease of handling during emergencies. It ensures excellent coverage for spill fires and provides extended discharge duration for effective suppression of fast-spreading flames.
Ideal for fuel stations, chemical warehouses, vehicle workshops, manufacturing plants, storage facilities, and commercial establishments.
The Portable Foam Fire Extinguisher plays a vital role in fire safety systems, especially in locations where flammable liquid hazards are common. Foam extinguishers not only knock down flames but also prevent re-ignition by forming a stable foam layer over the fire surface.
Unlike water-based extinguishers that may spread flammable liquids, foam is engineered to smother the fire by blocking oxygen and cooling the source simultaneously. This makes it one of the safest and most effective choices for Class B fires.
Designed for high efficiency and easy operation, the Portable Foam Fire Extinguisher is built with premium components that ensure long service life, consistent discharge flow, and dependable fire suppression performance at critical moments.
Foam Generation
When activated, the internal pressure forces the foam concentrate to mix with water, creating an expanding foam solution.
Surface Sealing
The foam forms a stable blanket over flammable liquid surfaces, cutting off oxygen supply and suppressing vapors.
Cooling Effect
The water content of the foam cools the fire source, reducing surface temperature and preventing re-ignition.
Uniform Discharge
The hose and nozzle system ensures even distribution of foam over large surface areas or spill fires.
Safe and Controlled Operation
The squeeze-grip valve allows the user to control the discharge rate for precision firefighting.
| Extinguisher Type | Portable Type | Mobile Type | ||
| Model | E0804- FM6S | E0804- FM9S | E0804- FM50 | E0804- FM100 |
| Available Size (kg) | 6 | 9 | 50 | 100 |
| Temperature Range | +5C to +60C | -30C to +60C | ||
| Working Pressure (bar) | 15 | |||
| Test Pressure(bar) | 27 | |||
| Standard | BSEN | |||
| LPCB Approved | ||||
Fuel Storage and Handling Areas
Foam extinguishers are highly effective for petrol, diesel, kerosene, solvents, and other flammable liquid fires.
Industrial Manufacturing Units
Suitable for machinery zones, processing plants, and production floors where combustible materials are present.
Commercial Establishments
Provides reliable fire protection in offices, malls, showrooms, and public buildings.
Warehouses and Logistics Hubs
Ideal for storage rooms, packing zones, and facilities containing cartons, wood, plastics, and fuel-based materials.
Vehicle Service Centers
Provides rapid suppression of oil, fuel, and engine-related fires.
Marine and Dock Facilities
Foam’s vapor-suppressing ability makes it ideal for oil-based fire risks common in marine operations.
Monthly Inspection
Check the pressure gauge, verify the safety pin and seal, and ensure the hose is unobstructed.
Foam Quality Check
Over time, foam concentrate may degrade. Periodic technical inspection ensures proper consistency and performance.
Valve and Nozzle Check
Inspect for cracks, corrosion, or deformation. Ensure smooth valve operation.
Hydrostatic Testing
Conduct pressure testing based on local regulatory standards to confirm cylinder strength and internal integrity.
Annual Servicing
Professional servicing ensures internal components, foam concentrate, and seals remain in optimal condition.
Excellent Coverage and Suppression
Foam provides a thick, vapor-sealing blanket that prevents the fire from spreading or reigniting.
Safe on Flammable Liquids
Unlike water, which can spread oil fires, foam suppresses them effectively and safely.
High Cooling Capability
Reduces surface temperature rapidly, offering superior fire control and post-fire safety.
Easy to Operate
The ergonomic design and controlled nozzle system make it simple even for non-technical users.
Durable and Reliable Build
The corrosion-resistant cylinder and high-quality valve assembly ensure long-term performance.
When maintained regularly, a Portable Foam Fire Extinguisher can offer up to 10–12 years of reliable service. The steel cylinder and internal components are built for durability, while periodic testing and servicing help maintain maximum extinguishing efficiency. Foam extinguishers require proper storage and annual maintenance to prevent concentrate degradation and ensure consistent performance.
Explore complete product specifications, compliance details, and installation information.
1. What types of fires can a Portable Foam Fire Extinguisher handle?
This extinguisher is specifically designed for Class A (solid combustibles such as wood, paper, and textiles) and Class B (flammable liquids including oils, paints, fuels). Foam works by forming a stable blanket that blocks oxygen and cools the fire source. However, it is not suitable for electrical fires unless the power supply is safely disconnected.
2. How does foam prevent re-ignition of flammable liquid fires?
The foam creates a vapor-sealing film over the surface of the liquid, preventing flammable vapors from escaping. Since vapor release is a primary cause of re-ignition, this sealing action ensures the fire remains extinguished. The cooling effect from the water component also eliminates residual heat that could restart the fire.
3. Is the Portable Foam Fire Extinguisher safe for indoor use?
Yes, foam extinguishers are safe for indoor environments such as offices, warehouses, and workshops. They do not produce harmful fumes and offer excellent coverage for surface fires. However, due to liquid discharge, minimal cleanup is required after use. Proper ventilation is recommended in enclosed rooms.
4. How often should the foam extinguisher be serviced?
A routine inspection should be done monthly to verify pressure and physical condition. Professional servicing is recommended annually, including foam concentrate checks to ensure its stability and effectiveness. Hydrostatic testing should follow regulatory schedules to confirm cylinder safety.
5. Can foam extinguishers be used on electrical equipment?
Foam is not recommended for energized electrical fires because it conducts electricity. However, if the power is switched off or isolated, foam can be used safely on Class A and Class B materials around electrical areas. For live electrical fires, COâ‚‚ or dry chemical extinguishers are more appropriate.
Protect your home, family, and business with industry-leading fire safety solutions—because seconds matter. From advanced smoke detectors to professional-grade extinguishers and smart alert systems, we’ve got you covered.
Please fill up the form